Sixth International Visual Field Symposium
Santa Margherita Ligure, May 27–31, 1984
Seiten
2011
|
Softcover reprint of the original 1st ed. 1985
Springer (Verlag)
978-94-010-8932-6 (ISBN)
Springer (Verlag)
978-94-010-8932-6 (ISBN)
Held at Santa Margherita Ligure, Italy, May 27-31,1984
The HF A is a computerized perimeter with a very comprehensive set of test point patterns, strategies and custom tests. The instrument employs several solutions which have proved useful in earlier computerized perimeters and several new concepts. The construction with stimulus generation through a projection system, input through a CRT, programmes stored in PROMs and a double disc drive for storage of test results makes it simple to adapt the instrument to future needs, whether these are new test algorithms or point patterns, different input or display screens or new statistical analysis programmes. All these changes could be made without modification of actual instrument hardware. REFERENCES 1. Dannheim, F. and Drance, S.M. Psycho visual disturbances in glaucoma. A study of temporal and spatial summation. Arch. Ophthalmol. 91: 463 -468 (1974). 2. Fankhauser, F. and Hiiberlin, H. Dynamic range and stray light. An estimate of the falsifying effect of stray light in perimetry. Documenta Ophthalmol. 50: 143-167 (1980). 3. Fankhauser, F., Hiiberlin, H. and Jenni, A. Octopus programs SAPRO and F. Two new principles for the analyses of the visual field. Graefes Arch. Klin. exp Ophthal- mo1216: 155-165 (1981).
4. Gramer, E. and Krieglstein, G.K. Zur Spezifitiit der iiberschwelligen Computer- perimetrie. Klin. Mbl. Augenheilk. 181; 373-375 (1982). 5. Gramer, E., Kontic, D. and Krieglstein, G.K. Die computerperimetrische Dar- stellung glaukomatoser Gesichtsfelddefekte in Abhangigkeit von der Stimulus- grosse. Ophthalmologica 183: 162-167 (1981).
The HF A is a computerized perimeter with a very comprehensive set of test point patterns, strategies and custom tests. The instrument employs several solutions which have proved useful in earlier computerized perimeters and several new concepts. The construction with stimulus generation through a projection system, input through a CRT, programmes stored in PROMs and a double disc drive for storage of test results makes it simple to adapt the instrument to future needs, whether these are new test algorithms or point patterns, different input or display screens or new statistical analysis programmes. All these changes could be made without modification of actual instrument hardware. REFERENCES 1. Dannheim, F. and Drance, S.M. Psycho visual disturbances in glaucoma. A study of temporal and spatial summation. Arch. Ophthalmol. 91: 463 -468 (1974). 2. Fankhauser, F. and Hiiberlin, H. Dynamic range and stray light. An estimate of the falsifying effect of stray light in perimetry. Documenta Ophthalmol. 50: 143-167 (1980). 3. Fankhauser, F., Hiiberlin, H. and Jenni, A. Octopus programs SAPRO and F. Two new principles for the analyses of the visual field. Graefes Arch. Klin. exp Ophthal- mo1216: 155-165 (1981).
4. Gramer, E. and Krieglstein, G.K. Zur Spezifitiit der iiberschwelligen Computer- perimetrie. Klin. Mbl. Augenheilk. 181; 373-375 (1982). 5. Gramer, E., Kontic, D. and Krieglstein, G.K. Die computerperimetrische Dar- stellung glaukomatoser Gesichtsfelddefekte in Abhangigkeit von der Stimulus- grosse. Ophthalmologica 183: 162-167 (1981).
Automatic Perimetry: Threshold Fluctuations.- Automatic Perimetry: New Instruments and Strategies.- Automatic Perimetry: Cartography.- Automatic Perimetry: General.- The Importance of Peripheral Visual Fields in Neuro-Ophthalmology.- Neuro-Ophthalmology: General.- Colour Perimetry.- Ergo-Perimetry.- Glaucoma.- Fundus Perimetry.- The Visual Field in Strabismus and Amblyopia.- General Topics.
Reihe/Serie | Documenta Ophthalmologica Proceedings Series ; 42 |
---|---|
Zusatzinfo | 608 p. |
Verlagsort | Dordrecht |
Sprache | englisch |
Maße | 155 x 235 mm |
Themenwelt | Sachbuch/Ratgeber ► Natur / Technik ► Garten |
Medizin / Pharmazie ► Medizinische Fachgebiete ► Augenheilkunde | |
ISBN-10 | 94-010-8932-9 / 9401089329 |
ISBN-13 | 978-94-010-8932-6 / 9789401089326 |
Zustand | Neuware |
Haben Sie eine Frage zum Produkt? |
Mehr entdecken
aus dem Bereich
aus dem Bereich
Obst- und Ziergehölze, Stauden, Kübel- und Zimmerpflanzen richtig …
Buch | Hardcover (2023)
Gräfe und Unzer (Verlag)
CHF 49,90
Buch | Hardcover (2023)
Bassermann (Verlag)
CHF 29,90