Nicht aus der Schweiz? Besuchen Sie lehmanns.de

Direct Analysis in Real Time Mass Spectrometry (eBook)

Principles and Practices of DART-MS

Yiyang Dong (Herausgeber)

eBook Download: EPUB
2017
Wiley-VCH Verlag GmbH & Co. KGaA
978-3-527-80371-2 (ISBN)

Lese- und Medienproben

Direct Analysis in Real Time Mass Spectrometry -
Systemvoraussetzungen
129,99 inkl. MwSt
(CHF 126,95)
Der eBook-Verkauf erfolgt durch die Lehmanns Media GmbH (Berlin) zum Preis in Euro inkl. MwSt.
  • Download sofort lieferbar
  • Zahlungsarten anzeigen
Clear, comprehensive, and state of the art, the groundbreaking book on the emerging technology of direct analysis in real time mass spectrometry

Written by a noted expert in the field, Direct Analysis in Real Time Mass Spectrometry offers a review of the background and the most recent developments in DART-MS. Invented in 2005, DART-MS offers a wide range of applications for solving numerous analytical problems in various environments, including food science, forensics, and clinical analysis. The text presents an introduction to the history of the technology and includes information on the theoretical background, for exampleon the ionization mechanism. Chapters on sampling and coupling to different types of mass spectrometers are followed by a comprehensive discussion of a broad range of applications.

Unlike most other ionization methods, DART does not require laborious sample preparation, as ionization takes place directly on the sample surface. This makes the technique especially attractive for applications in forensics and food science. Comprehensive in scope, this vital text:

-Sets the standard on an important and emerging ionization technique
-Thoroughly discusses all the relevant aspects from instrumentation to applications
-Helps in solving numerous analytical problems in various applications, for example food science, forensics, environmental and clinical analysis
-Covers mechanisms, coupling to mass spectrometers, and includes information on challenges and disadvantages of the technique

Academics, analytical chemists, pharmaceutical chemists, clinical chemists, forensic scientists, and others will find this illuminating text a must-have resource for understanding the most recent developments in the field.

Yiyang Dong is full professor and director of Food Safety & Risk Assessment Laboratory of Beijing University of Chemical Technology (BUCT) in Beijing, China. He is frequently invited as reviewer for journals such as Biosensors and Bioelectronics, Analyst, Analytical Methods, and Journal of Molecular Recognition.

Introduction of mass spectrometry and ambient ionization techniques
The mechanism of DART ionization and facilities
The sampling and analyte enrichment strategies for DART-MS
Interfacing of DART with various mass analyzers
Optimization of DART and relevant mass parameters
Applications of DART-MS in food and agro-products analysis
Application of DART-MS in drug and forensic analysis
Application of DART-MS for industrial products inspection
Application of DART-MS for environmental contaminants analysis
Application of DART-MS for clinical and pharmacological analysis
Disadvantages and visions of DART-MS

Erscheint lt. Verlag 29.11.2017
Sprache englisch
Themenwelt Naturwissenschaften Chemie
Schlagworte Analytische Chemie • Analytische Chemie / Forensik • Applications of DART-MS • Applications of Direct Analysis in Real Time Mass Spectrometry • Chemie • Chemistry • Direct Analysis in Real Time Mass Spectrometry • emerging ionization technique • Forensics • Guide to DART-MS • <p>Guide to Direct Analysis in Real Time Mass Spectrometry • Massenspektrometrie • Mass Spectrometry • Pharmaceutical & Medicinal Chemistry • Pharmazeutische u. Medizinische Chemie • Practices of DART-MS • Practices of Direct Analysis in Real Time Mass Spectrometry • principles and practices • Principles of DART-MS • Principles of Direct Analysis in Real Time Mass Spectrometry • Reference to DART-MS • Reference to Direct Analysis in Real Time Mass Spectrometry • Resource for Direct Analysis in Real Time Mass Spectrometry • Resource to DART-MS • Understanding DART-MS • Understanding Direct Analysis in Real Time Mass Spectrometry • Yiyang Dong</p>
ISBN-10 3-527-80371-8 / 3527803718
ISBN-13 978-3-527-80371-2 / 9783527803712
Informationen gemäß Produktsicherheitsverordnung (GPSR)
Haben Sie eine Frage zum Produkt?
EPUBEPUB (Adobe DRM)
Größe: 14,5 MB

Kopierschutz: Adobe-DRM
Adobe-DRM ist ein Kopierschutz, der das eBook vor Mißbrauch schützen soll. Dabei wird das eBook bereits beim Download auf Ihre persönliche Adobe-ID autorisiert. Lesen können Sie das eBook dann nur auf den Geräten, welche ebenfalls auf Ihre Adobe-ID registriert sind.
Details zum Adobe-DRM

Dateiformat: EPUB (Electronic Publication)
EPUB ist ein offener Standard für eBooks und eignet sich besonders zur Darstellung von Belle­tristik und Sach­büchern. Der Fließ­text wird dynamisch an die Display- und Schrift­größe ange­passt. Auch für mobile Lese­geräte ist EPUB daher gut geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen eine Adobe-ID und die Software Adobe Digital Editions (kostenlos). Von der Benutzung der OverDrive Media Console raten wir Ihnen ab. Erfahrungsgemäß treten hier gehäuft Probleme mit dem Adobe DRM auf.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen eine Adobe-ID sowie eine kostenlose App.
Geräteliste und zusätzliche Hinweise

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Mehr entdecken
aus dem Bereich
Eigenschaften, Verarbeitung, Konstruktion

von Erwin Baur; Dietmar Drummer; Tim A. Osswald; Natalie Rudolph

eBook Download (2022)
Carl Hanser Verlag GmbH & Co. KG
CHF 68,35