Nicht aus der Schweiz? Besuchen Sie lehmanns.de

Vitreo-retinal Surgery

Progress III
Buch | Hardcover
XVIII, 234 Seiten
2008
Springer Berlin (Verlag)
978-3-540-69461-8 (ISBN)

Lese- und Medienproben

Vitreo-retinal Surgery -
CHF 104,75 inkl. MwSt
  • Titel ist leider vergriffen;
    keine Neuauflage
  • Artikel merken
Leading surgeons in the field vitreoretinal surgery were recruited for this book to offer their insights into the sutureless techniques they perform. The result is a volume that is indispensable for continuous education and advanced training in this field.
Since the introduction of vitrectomy in the 1970s, vitreoretinal surgery has rapidly developed. Initially, new instrumentations were created to facilitate intraocular maneuvers and to treat almost all the vitreoretinal pathologies. High speed vitrectome probs, forceps, scissors, endolaser probes, and new light sources (xenon/photon light) permit us to perform safer surgeries.

However, in the last few years the approach to vitreoretinal surgery has changed with the introduction of small gauge instruments and sutureless surgery. At present there is still confusion among vitreoretinal surgeons about the use of 25-, 23- or 20-gauge sutureless systems.

Leading surgeons in the field were recruited to offer their insights into the sutureless techniques they perform.

Topics dealt with in the book include: - fluidics and technical characteristics of 23- and 25-gauge systems, - basic vitrectomy techniques of 23- and 25-gauge systems, - sclerotomy characteristics of the sutureless approach, - advantages and disadvantages of the sutureless technique, - vitreoretinal pathologies treated with 23- and 25-gauge systems, - complications of the sutureless technique, - current clinical data.

25-Gauge Instrumentation - Engineering Challenges and Tradeoffs.- 25-gauge Vitreous Surgery: Getting Started.- Comparison of 25-gauge Trocar/Cannula Wound Healing and Remodeling with In Vivo Vitrector Flow Analysis.- 25-Gauge, Sutureless, Trans-Conjunctival Vitrectomy.- 23/25 gauge trocars' insertion technique/ 23/25 gauge "one-step" instrumentation.- 25-23 gauge vitrectomy for Rhegmatogenous Retinal Detachment.- 23-Gauge, Sutureless, Trans-Conjunctival Vitrectomy.- 25 gauge Macular Surgery.- 25-gauge Sutureless Vitrectomy for Diabetic retinopathy.- 25 gauge Perfluorocarbon Perfused Vitrectomy.- 25 gauge Vitrectomy for vitreous floaters.- 25 g vitrectomy in infectious endophthalmitis.- 25-gauge system for Vitreous and Retinal/Choroidal Biopsy.- Complications of 25 Gauge Vitrectomy.- The use of 25 gauge systems in the management of trauma.- Small gauge approach in Pedriatic VR surgery.- A Comparison of 20 versus 25 gauge Vitrectomy: Does Size Matter? - 20 gauge sutureless vitrectomy with trocar system.- Combined Phaco/25g Vitrectomy historical overview of microincision surgery.- 20 gauge sutureless vitrectomy without trocar system.- Pearls from the Experts.

Erscheint lt. Verlag 4.11.2008
Reihe/Serie Essentials in Ophthalmology
Sprache englisch
Maße 193 x 260 mm
Gewicht 792 g
Einbandart gebunden
Themenwelt Medizin / Pharmazie Medizinische Fachgebiete
Schlagworte Augenchirurgie • Netzhaut
ISBN-10 3-540-69461-7 / 3540694617
ISBN-13 978-3-540-69461-8 / 9783540694618
Zustand Neuware
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich