Intercomparison of Personal Dose Equivalent Measurements by Active Personal Dosimeters
Final Report of a Joint IAEA–EURADOS Project
Seiten
2007
IAEA (Verlag)
978-92-0-106607-7 (ISBN)
IAEA (Verlag)
978-92-0-106607-7 (ISBN)
The IAEA organised an intercomparison, using test criteria from two international standards. Additionally, simulated workplace fields were used for testing the active personal dosimeter reactions to pulsed X ray fields and mixed gamma/X ray fields. This is the first time that results of such a comparison have been published.
Active personal dosimeters (APDs) are widely used in many countries to provide on the spot dose information to persons exposed to radiation. Their use as legal dosimeters is already established in a few countries. In the majority of countries, APDs have not undergone accreditation programmes or intercomparisons. The IAEA, in cooperation with EURADOS, organized an intercomparison, using test criteria from two international standards (IEC 61526 and IEC 61283). Additionally, simulated workplace fields were used for testing the APD reactions to pulsed X ray fields and mixed gamma/X ray fields. This is the first time that results of such a type of comparison have been published, representing a step of great importance for APD end users in medical diagnostic and surgery X ray applications. This report may be used by Member States as a source of information on new instruments which could be used in the near future as legal dosimeters, combining the advantages of small size and instant readout of dose rate and dose with computerized dose keeping.
Active personal dosimeters (APDs) are widely used in many countries to provide on the spot dose information to persons exposed to radiation. Their use as legal dosimeters is already established in a few countries. In the majority of countries, APDs have not undergone accreditation programmes or intercomparisons. The IAEA, in cooperation with EURADOS, organized an intercomparison, using test criteria from two international standards (IEC 61526 and IEC 61283). Additionally, simulated workplace fields were used for testing the APD reactions to pulsed X ray fields and mixed gamma/X ray fields. This is the first time that results of such a type of comparison have been published, representing a step of great importance for APD end users in medical diagnostic and surgery X ray applications. This report may be used by Member States as a source of information on new instruments which could be used in the near future as legal dosimeters, combining the advantages of small size and instant readout of dose rate and dose with computerized dose keeping.
Reihe/Serie | IAEA TECDOC Series |
---|---|
Verlagsort | Vienna |
Sprache | englisch |
Maße | 152 x 229 mm |
Themenwelt | Medizinische Fachgebiete ► Radiologie / Bildgebende Verfahren ► Nuklearmedizin |
ISBN-10 | 92-0-106607-4 / 9201066074 |
ISBN-13 | 978-92-0-106607-7 / 9789201066077 |
Zustand | Neuware |
Haben Sie eine Frage zum Produkt? |
Mehr entdecken
aus dem Bereich
aus dem Bereich
Buch | Softcover (2022)
Lehmanns Media (Verlag)
CHF 55,90
Lehrbuch für Breast Care Nurses und Fachpersonen in der Onkologie
Buch | Hardcover (2020)
Hogrefe (Verlag)
CHF 63,00