Offers advice on applying specific information within the framework of the HRTM for assessing occupational and environmental exposures and for interpreting bioassay data. This work provides: a summary of how the HRTM treats a topic; information on the reference values of relevant parameters; and, guidance on choosing between default values.
The ICRP Publication 66 Human Respiratory Tract Model for Radiological Protection (HRTM) has been applied to calculate dose coefficients (doses per unit intake) and bioassay functions in ICRP Publications 68, 71, 72 and 78. For these purposes, ICRP assigned numerical values to a range of model parameters, such as the size of the inhaled particles and the breathing rate of the subjects. These are known as `default’ or `reference’ values, and were chosen to be typical, representative values. In any particular situation the actual values of many parameters can be considerably different from the reference values. Usually, doses from intakes of radionuclides are low compared with the relevant limit or constraint, and the resulting difference is unimportant. There are, however, circumstances where more reliable assessments of intake and dose are desirable. This Guidance Document therefore gives advice on applying specific information within the framework of the HRTM for assessing occupational and environmental exposures and for interpreting bioassay data. Chapters on each aspect of the model (morphometry, physiology, deposition, clearance, gases and vapours, dosimetry) provide:
A summary of how the HRTM treats that topic;
Information on the reference values of relevant parameters;
Guidance on choosing between default values;
Information on how doses and bioassay quantities (lung retention, urine, and faecal excretion) vary with the values of selected parameters, giving guidance on the importance of obtaining specific information;
Simple examples of the use of specific information relating to the topic.
Annexes give additional information for those directly involved in applying the HRTM to specific situations, including guidance on obtaining parameter values. A brief overview is given of the deposition, characterisation, and sampling of aerosols, with references to further information, as there are relevant text books already available. Issues specific to radioactive aerosols, such as low particle number concentrations for high specific activity materials are, however, addressed. Guidance on obtaining information about absorption of inhaled radionuclides into blood is given in greater detail, because this is a topic on which ICRP has traditionally given guidance, and because a compilation of such information is not readily available elsewhere. Several detailed examples are also provided. One involves assessment of an individual’s intake and committed dose from comprehensive bioassay monitoring data. The others deal with the derivation of HRTM absorption parameter values from experimental data, and their application, with additional information on e.g. size distribution, to calculate dose coefficients and interpret bioassay data.
The ICRP Publication 66 Human Respiratory Tract Model for Radiological Protection (HRTM) has been applied to calculate dose coefficients (doses per unit intake) and bioassay functions in ICRP Publications 68, 71, 72 and 78. For these purposes, ICRP assigned numerical values to a range of model parameters, such as the size of the inhaled particles and the breathing rate of the subjects. These are known as `default’ or `reference’ values, and were chosen to be typical, representative values. In any particular situation the actual values of many parameters can be considerably different from the reference values. Usually, doses from intakes of radionuclides are low compared with the relevant limit or constraint, and the resulting difference is unimportant. There are, however, circumstances where more reliable assessments of intake and dose are desirable. This Guidance Document therefore gives advice on applying specific information within the framework of the HRTM for assessing occupational and environmental exposures and for interpreting bioassay data. Chapters on each aspect of the model (morphometry, physiology, deposition, clearance, gases and vapours, dosimetry) provide:
A summary of how the HRTM treats that topic;
Information on the reference values of relevant parameters;
Guidance on choosing between default values;
Information on how doses and bioassay quantities (lung retention, urine, and faecal excretion) vary with the values of selected parameters, giving guidance on the importance of obtaining specific information;
Simple examples of the use of specific information relating to the topic.
Annexes give additional information for those directly involved in applying the HRTM to specific situations, including guidance on obtaining parameter values. A brief overview is given of the deposition, characterisation, and sampling of aerosols, with references to further information, as there are relevant text books already available. Issues specific to radioactive aerosols, such as low particle number concentrations for high specific activity materials are, however, addressed. Guidance on obtaining information about absorption of inhaled radionuclides into blood is given in greater detail, because this is a topic on which ICRP has traditionally given guidance, and because a compilation of such information is not readily available elsewhere. Several detailed examples are also provided. One involves assessment of an individual’s intake and committed dose from comprehensive bioassay monitoring data. The others deal with the derivation of HRTM absorption parameter values from experimental data, and their application, with additional information on e.g. size distribution, to calculate dose coefficients and interpret bioassay data.
Back to the Future - the Prequel Preface Glossary of Terms Abstract Introduction Morphometric model of the respiratory tract Respiratory physiology Deposition in the respiratory tract Clearance from the respiratory tract Inhalation of gases and vapours Dosimetric model of the respiratory tract Gastrointestinal absorption Systemic activity References Annex A: tables of reference values Annex B: Deposition, characterisation, and sampling of radioactive aerosols
Reihe/Serie | Annals of the ICRP |
---|---|
Verlagsort | London |
Sprache | englisch |
Gewicht | 577 g |
Themenwelt | Medizinische Fachgebiete ► Innere Medizin ► Pneumologie |
Medizinische Fachgebiete ► Radiologie / Bildgebende Verfahren ► Radiologie | |
ISBN-10 | 0-08-044267-6 / 0080442676 |
ISBN-13 | 978-0-08-044267-9 / 9780080442679 |
Zustand | Neuware |
Haben Sie eine Frage zum Produkt? |
Mehr entdecken
aus dem Bereich
aus dem Bereich
Aus der Praxis für die Praxis
Buch (2022)
Thieme (Verlag)
CHF 99,40
International Trauma Life Support (ITLS)
Buch | Softcover (2024)
Hogrefe AG (Verlag)
CHF 91,00