Nicht aus der Schweiz? Besuchen Sie lehmanns.de
Volume 45, Issue 3, An Issue of Orthopedic Clinics -  Asif M. Ilyas

Volume 45, Issue 3, An Issue of Orthopedic Clinics (eBook)

eBook Download: PDF | EPUB
2014 | 1. Auflage
100 Seiten
Elsevier Health Sciences (Verlag)
978-0-323-31186-1 (ISBN)
90,43 € (CHF 88,35)
Systemvoraussetzungen
80,66 € (CHF 78,80)
Systemvoraussetzungen
Der eBook-Verkauf erfolgt durch die Lehmanns Media GmbH (Berlin) zum Preis in Euro inkl. MwSt.
  • Download sofort lieferbar
  • Zahlungsarten anzeigen
Each issue of Orthopedic Clinics offers clinical review articles on the most cutting edge technologies, techniques, and more in the field. Major topic areas include: adult reconstruction, upper extremity, pediatrics, trauma, oncology, hand, foot and ankle.
Each issue of Orthopedic Clinics offers clinical review articles on the most cutting edge technologies, techniques, and more in the field. Major topic areas include: adult reconstruction, upper extremity, pediatrics, trauma, oncology, hand, foot and ankle.

Component Selection in Revision Total Hip Arthroplasty


Antonia F. Chen, MD, MBAantonia.chen@rothmaninstitute.com and William J. Hozack, MD,     Department of Orthopaedic Surgery, Rothman Institute, 925 Chestnut Street, Philadelphia, PA 19107, USA

∗Corresponding author.

Component selection for revision total hip arthroplasty is important for creating a stable hip, providing offset to maximize joint mechanics, and restoring appropriate leg lengths. On the femoral side, fully porous coated stems, modular tapered stems, and proximal femoral replacements can be used depending on the level of bone loss. For the acetabulum, smaller defects can be contained using second-generation porous coating hemispherical cups, whereas larger acetabular defects can be contained with cup cages, cages, or custom triflange implants. In addition, acetabular liners can improve stability through altered cup version, dual mobility, or constraint of the femoral head.

Keywords

Revision total hip arthroplasty

Fully porous coated stems

Modular components

Trabecular metal

Acetabular augments

Cages

Key points


• Paprosky acetabular and femoral classification systems are important for diagnosis, prognosis, and treatment of bone loss when choosing revision total hip arthroplasty implants.

• Revision femoral stems provide diaphyseal fixation using either fully porous coated cylindrical stems or modular tapered stems for almost all bone deficiencies.

• For complete proximal bone loss, proximal femoral replacements may be used or an allograft-prosthetic composite can be grafted to existing host bone.

• Most acetabular defects can be addressed with second-generation porous coating hemispherical cups with or without the addition of metal augments.

• The preferred method for addressing severe acetabular defects is the cup-cage construct, in which a second-generation porous coating cup is held in place with a cage and secured with screws into the ischium and ilium. Bone loss rarely requires the use of a custom triflange implant.

• Acetabular liners can be used to change acetabular version, use effectively larger femoral heads through dual mobility liners, or constrain the femoral head.

Introduction


Component selection for revision total hip arthroplasty (THA) is dictated by choosing components that create a stable hip, restore appropriate leg lengths, and provide offset to maximize joint mechanics. Multiple factors go into the decision-making process for which components to use, including the amount of bone loss present and accounting for the components that are currently in place. For the femur, determining the geometry of the remaining bone helps to guide orthopedic surgeons to use fully porous coated stems for metaphyseal bone loss, modular stems that provide various stem versions, and proximal femoral replacements (PFRs) for reconstructions in which there is great proximal bone loss and no attachment for the abductors. Smaller acetabular defects can be contained by using hemispherical cups with second-generation porous coatings with or without metal augments or bone graft, whereas larger acetabular defects can be contained with cages or custom triflange implants. In addition, specific acetabular liners can be placed to alter the version of the cup by a set number of degrees, provide articulation through dual mobility liners, or constrain the femoral head. This article provides guidance as to which components to use in THA revisions.

Revision femoral components


Choosing femoral components in revision THA depends on the type of fixation needed to stabilize a prosthesis within a femur with bone loss. Although metaphyseal fixation is often used in primary THA stems with wedge and taper stems, most stems used in revision THA are designed for diaphyseal fixation, because the metaphysis can be weakened or even absent in the revision setting. If too much proximal femoral bone is missing, then a PFR may need to be used. The options for femoral components in revision THA are described later.

Bone Loss Classification


The most useful classification system is the Paprosky classification,1 which is both prognostic and helps to direct treatment options. For type I defects, there is minimal bone loss in the metaphyseal region and the diaphysis is intact. In this setting, a primary THA stem may be used. For type II defects, the femur has extensive metaphyseal cancellous bone loss, but the diaphysis is still intact. Type III defects are characterized by severe bone damage and are classified into 2 groups. Type IIIA defects have severe compromise of the metaphyseal bone, but have greater than 4 cm of bone remaining in the diaphysis. Type IIIB defects also have an unsupportive metaphysis, but have less than 4 cm of bone in the diaphysis to provide for fixation. In addition, type IV defects have extensive metaphyseal and diaphyseal bone loss with an unsupportive isthmus and a widened femoral canal.

Fully Porous Coated Cylindrical Stems


Fully porous coated stems require adequate diaphyseal bone present for fixation. These stems are cylindrical and achieve an interference fit in the diaphysis, and studies have shown the need for greater than 4 cm of intact diaphyseal bone for secure fixation.2 The severity of the defect determines the long-term fixation and survivorship of these stems,3,4 because Paprosky type I and II defects can be treated with fully porous coated stems5 as long as the femoral canal is less than 19 mm in width.6,7 Long-term results show that using fully porous coated stems leads to long survivorship and high rates of osseointegration determined by radiographic studies,8 but one of the side effects is increased thigh pain and proximal stress shielding, because most of the stress transfer to bone occurs in the diaphysis.9

Modular Tapered Stems


Modular cementless stems are commonly used in revision THA (Fig. 1), because the proximal and distal femur are individually prepared to accommodate a prosthesis that fills bone defects. These implants can provide good diaphyseal fixation, limb length discrepancies can be restored,10 and the version of the implant can be set to provide joint stability and maximize joint mechanics.11 Although these modular stems can vary the distal stem configuration,12 the tapered conical stem is now favored and has the best results. Studies show that modular tapered stems had lower failure rates, better osseointegration, and decreased revision rates compared with cylindrical stems.13,14 These modular, tapered stems can be used to treat any level of bone damage, but are particularly effective (compared with cylindrical fully porous coated stems) for Paprosky type III femoral defects, with demonstrated 75% to 94% survivorship at 4.5 to 10 years.1520 Using proper technique, these implants have a low failure rate, but can subside if not fitted tightly, or can fracture at the interface between the neck and the stem of the prosthesis if that junction is not supported by bone.21,22


Fig. 1 Modular femoral stem. (A) Implant. (B) Radiograph. ([A] Courtesy of Howmedica Osteonics Corp, Mahwah (NJ); with permission.)

Allograft-Prosthetic Composite


Although modular stems can also be used to treat Paprosky type IV femoral defects, allograft-prosthetic composites (APCs) are another option for replacing bone loss by using a proximal femoral allograft and cementing or press fitting a stable implant into the allograft.23 Distal fixation can be achieved by providing step cuts for fixation, or tunneling the graft bone into host bone (intussusception) for Paprosky type IV femurs. APCs were first used to reconstruct limbs in dogs with osteosarcoma who underwent limb-sparing surgery,24 and they were subsequently used in revision THA to treat circumferential defects of greater than 3 cm from the calcar.25 More current studies recommend using APCs in Paprosky type III and IV defects, with 69% survivorship at 10 years.26 This method of fixation is beneficial because it restores bone stock, allows for load sharing of the revision construct with host bone, provides a biological anchor for abductor attachment, and improves the ease of reoperation if bone has incorporated by future revision surgery. However, implanting an APC is a technically demanding procedure, and because allograft is used there is a risk of fracture because the construct is not as strong as metal implants, there is a risk of disease transmission, and the graft may not incorporate and may lead to nonunion or resorption.

PFR


In the case of massive proximal bone loss in which treatment with the aforementioned implants is...

Erscheint lt. Verlag 8.9.2014
Sprache englisch
Themenwelt Medizinische Fachgebiete Chirurgie Unfallchirurgie / Orthopädie
Medizin / Pharmazie Medizinische Fachgebiete Orthopädie
ISBN-10 0-323-31186-5 / 0323311865
ISBN-13 978-0-323-31186-1 / 9780323311861
Haben Sie eine Frage zum Produkt?
PDFPDF (Adobe DRM)
Größe: 11,3 MB

Kopierschutz: Adobe-DRM
Adobe-DRM ist ein Kopierschutz, der das eBook vor Mißbrauch schützen soll. Dabei wird das eBook bereits beim Download auf Ihre persönliche Adobe-ID autorisiert. Lesen können Sie das eBook dann nur auf den Geräten, welche ebenfalls auf Ihre Adobe-ID registriert sind.
Details zum Adobe-DRM

Dateiformat: PDF (Portable Document Format)
Mit einem festen Seiten­layout eignet sich die PDF besonders für Fach­bücher mit Spalten, Tabellen und Abbild­ungen. Eine PDF kann auf fast allen Geräten ange­zeigt werden, ist aber für kleine Displays (Smart­phone, eReader) nur einge­schränkt geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen eine Adobe-ID und die Software Adobe Digital Editions (kostenlos). Von der Benutzung der OverDrive Media Console raten wir Ihnen ab. Erfahrungsgemäß treten hier gehäuft Probleme mit dem Adobe DRM auf.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen eine Adobe-ID sowie eine kostenlose App.
Geräteliste und zusätzliche Hinweise

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

EPUBEPUB (Adobe DRM)

Kopierschutz: Adobe-DRM
Adobe-DRM ist ein Kopierschutz, der das eBook vor Mißbrauch schützen soll. Dabei wird das eBook bereits beim Download auf Ihre persönliche Adobe-ID autorisiert. Lesen können Sie das eBook dann nur auf den Geräten, welche ebenfalls auf Ihre Adobe-ID registriert sind.
Details zum Adobe-DRM

Dateiformat: EPUB (Electronic Publication)
EPUB ist ein offener Standard für eBooks und eignet sich besonders zur Darstellung von Belle­tristik und Sach­büchern. Der Fließ­text wird dynamisch an die Display- und Schrift­größe ange­passt. Auch für mobile Lese­geräte ist EPUB daher gut geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen eine Adobe-ID und die Software Adobe Digital Editions (kostenlos). Von der Benutzung der OverDrive Media Console raten wir Ihnen ab. Erfahrungsgemäß treten hier gehäuft Probleme mit dem Adobe DRM auf.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen eine Adobe-ID sowie eine kostenlose App.
Geräteliste und zusätzliche Hinweise

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Mehr entdecken
aus dem Bereich