Nicht aus der Schweiz? Besuchen Sie lehmanns.de
Interfaces in Total Hip Arthroplasty -

Interfaces in Total Hip Arthroplasty

Ian D. Learmonth (Herausgeber)

Buch | Softcover
168 Seiten
2012 | Softcover reprint of the original 1st ed. 2000
Springer London Ltd (Verlag)
978-1-4471-1150-4 (ISBN)
CHF 74,85 inkl. MwSt
This book incorporates the experience of numerous experts who explore contemporary opinion of how best to rationalise and optimise the interfaces at total hip replacement to provide the most favourable and durable results. The survival of a total hip replacement depends principally on the enduring integrity of the fixation interfaces and of the articular interface. The design of the stem and the material properties of cement largely determine the state of the component-cement inter­ face, while the bone-cement interface is significantly influenced by both mechanical and biological factors. The surface finish and shape of cementless implants are designed to preserve the integrity of biological fixation (osseo-integration) at the bone-component interface. Once again, both mechanical and biological factors have to be considered, while bioactive coatings accelerate bone ongrowth. Metal-on-polyethylene is the most widely used articular interface. However, it has been suggested that wear of polyethylene is one of the major factors contributing to failure of total hip replacements. The increasing prevalence of total hip replacement in younger patients has stimulated the investigation of alternative, more durable couples -including ceramic-polyethylene, ceramic-ceramic and metal-on-metal. Modularity provides greater intra-operative flexibility, but each new modular interface introduces new mechanisms of failure. These need to be anticipated and appropriate measures taken to avoid them. Hopefully this book will provide a better understanding of the factors that contribute to stable interfaces and long-term survival of total hip arthroplasty.

Section I Component-Cement-Interface.- 1 Titanium Femoral Component Fixation and Experience with a Cemented Titanium Prosthesis.- 2 The Time-dependent Properties of Polymethylmethacrylate Bone Cement: the Interaction of Shape of Femoral Stems, Surface Finish and Bone Cement.- 3 Femoral Stem Design and Cement Mantle Stress.- Section II Cement-Bone Interface.- 4 Histological Analysis of the Interface.- 5 Mechanical Analysis of the Interface.- Section III Modular Interface.- 6 Clinical Implications of Component Modularity in Total Hip Replacement.- Section IV Component-Bone Interface.- 7 Component Bone Interface in Cementless Hip Arthroplasty.- 8 Importance of Prosthesis Design and Surface Structure for the Primary and Secondary Stability of Uncemented Hip Joint Prostheses.- Section V Articular Interface.- 9 Polyethylene as a Bearing Surface.- 10 The Metal/Polyethylene Interface.- 11 Metal on Metal Articulation in Total Hip Replacement.- 12 Alumina on Polyethylene Bearings.- 13 Ceramic on Ceramic Bearing Surfaces.- Section VI Infected Interface.- 14 Periprosthetic Infection — Bacteria and the Interface Between Prosthesis and Bone.

Zusatzinfo XII, 168 p.
Verlagsort England
Sprache englisch
Maße 193 x 270 mm
Themenwelt Medizinische Fachgebiete Chirurgie Unfallchirurgie / Orthopädie
Medizinische Fachgebiete Innere Medizin Rheumatologie
Medizinische Fachgebiete Radiologie / Bildgebende Verfahren Radiologie
Schlagworte Hip Arthroplasty • Interface • Mechanics • orthopaedic surgery
ISBN-10 1-4471-1150-8 / 1447111508
ISBN-13 978-1-4471-1150-4 / 9781447111504
Zustand Neuware
Haben Sie eine Frage zum Produkt?
Mehr entdecken
aus dem Bereich
für Studium und Praxis unter Berücksichtigung des …

von Markus Müller; Achim Elsen; Matthias Eppinger

Buch | Softcover (2022)
Medizinische Vlgs- u. Inform.-Dienste (Verlag)
CHF 39,20