Bioceramics and Alternative Bearings in Joint Arthroplasty (eBook)
XVII, 321 Seiten
Steinkopff (Verlag)
978-3-7985-1635-9 (ISBN)
Large diameter femoral and acetabular components.- Head Diameter of 36mm: New alumina on alumina bearing surfaces.- All ceramic tripolar Total Hip Arthroplasty: experimental data and clinical results.- Clinical advantages with large diameter heads.- 36mm Ceramic head for “difficult” cases.- Resurfacing in total hip replacement.- Seven years of experience in MoM resurfacing: Results and open questions.- Surgeon and resurfacing: considerations after a long experience.- Hip Resurfacing — a superior articulation concept?.- Consideration on disadvantages and problems of resurfacing.- In vitro biomechanical properties of a hip resurfacing system.- Comparison of functional activity of hip resurfacing with total hip arthroplasty.- Hard-hard bearing systems.- Radiological development of an alumina metal back cup during 5 years.- Metal Ion Hypersensitivity in Metal-on-Metal Hip Arthroplasty.- 28mm Head in Ceramic/Ceramic Total Hip Replacement.- Ceramic Bearings Enlarging the Range of Indications for Bipolar Prostheses.- Kinematic evaluation of total hip arthroplasty with various bearing materials.- Total hip replacement with all alumina bearings in patients under 30 years of age.- Ceramic knee.- PE wear in ceramic/PE bearing surface in total knee arthroplasty: Clinical experiences of more than 24 years.- Hypersensitivity reactions in association to arthroplasty.- Ceramic Knee Design.- Ceramic knee endoprostheses: reality or future?.- Hip Revision.- Comparison of clinical results between Ceramic-Ceramic Bearings and Metal on Polyethylene in Total Hip Arthroplasty.- Revision strategy after metal on metal THR failure: Conversion to ceramic on ceramic.- Modular neck and ceramic on ceramic coupling in revision total hip arthroplasty.- Experience with BIOLOX® option revision heads.- Acetabular cup revision: pitfalls and solutions.- Revision strategies in total hip arthroplasty with respect to articulation materials.- Tribology.- Hip Joint Simulators: State of the Art.- Highly Crosslinked Ultra High Molecular Weight Polyethylene- (UHMWPE-) Acetabular Liners in combination with 28mm BIOLOX® heads.- Wear of Highly Crosslinked Polyethylene against Cobalt Chrome and Ceramic femoral heads.- US perspective on hip simulator wear testing of BIOLOX® delta in’ severe’ test modes.- Comparison of polythene liners with alumina liners in hydroxyapatite hip arthroplasty.- Edge Loading and Squeaking in Third Generation Ceramic-on-ceramic Bearings.- Tricks and tips: how to manage the implantation of ceramic implants.- Tricks and tips in every day utilization of ceramic on ceramic coupling.- Neck Modularity and CE/CE systems.- Off-set and ceramic on ceramic bearing.- Ceramic on ceramic cementless total hip arthroplasty in arthritis following congenital hip disease: an algorithm of the surgical treatment.- 32mm alumina on alumina hip replacement for femoral neck fracture.- Is there really a “safe zone” for the placement of total hip components?.- Tips of the trade: avoiding problems with ceramic components in THR.- Future Applications.- Direct to bone — possible ceramic solutions for monolithic hip implants.- Surface Activation of Implants.- Application of Bone Morphogenetic Proteins on Solid Implants.- Future applications in ceramics.- Poster.- The use of a ceramic “sandwich cup” in 140 hip arthroplasty with a 5 years follow-up or more.- THR Charnley type with Zr/Pe Bearing results at more than 5 years FU.- Wear Performance of Carbon Fibre Reinforced Implantable PEEK against BIOLOX® Forte and BIOLOX® Delta.- Big diameter ball heads on Corail Stem: Rational indication and advantages.- The Role of Pre-Irradation Crystallinity on the Oxidation Resistance of UHMWPE.- The Effect of Pressure-Annealing on the Oxidation Resistance of Irradiated UHMWPE.- Wear Simulator Study of the Tripolar All Ceramic Hip Prosthesis.- Metallic but not ceramic wear particles increase prostaglandin E2 release and interleukin-1? (IL-1?) gene expression in human blood monocytes in vitro.- BMP-2 modified ingrowth characteristics of coated hydroxyapatite-titanium implants in aged sheep.- Ultimate Compression Strength Testing of Alumina Ceramic Femoral Heads in Revision.- BIOLOX® option: A new revision strategy with BIOLOX® ceramics.- Duolox®, a ceramic Bipolar System for Hemiarthroplasty.
Erscheint lt. Verlag | 18.10.2006 |
---|---|
Reihe/Serie | Ceramics in Orthopaedics | Ceramics in Orthopaedics |
Zusatzinfo | XVII, 321 p. 177 illus. |
Verlagsort | Heidelberg |
Sprache | englisch |
Themenwelt | Medizin / Pharmazie ► Medizinische Fachgebiete ► Orthopädie |
Schlagworte | Arthroplasty • Bioceramics • Biolox • Biomechanics • Ceramics • Ceramtec • Hip Arthroplasty • Total Joint Replacement |
ISBN-10 | 3-7985-1635-9 / 3798516359 |
ISBN-13 | 978-3-7985-1635-9 / 9783798516359 |
Haben Sie eine Frage zum Produkt? |
Größe: 14,8 MB
DRM: Digitales Wasserzeichen
Dieses eBook enthält ein digitales Wasserzeichen und ist damit für Sie personalisiert. Bei einer missbräuchlichen Weitergabe des eBooks an Dritte ist eine Rückverfolgung an die Quelle möglich.
Dateiformat: PDF (Portable Document Format)
Mit einem festen Seitenlayout eignet sich die PDF besonders für Fachbücher mit Spalten, Tabellen und Abbildungen. Eine PDF kann auf fast allen Geräten angezeigt werden, ist aber für kleine Displays (Smartphone, eReader) nur eingeschränkt geeignet.
Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen dafür einen PDF-Viewer - z.B. den Adobe Reader oder Adobe Digital Editions.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen dafür einen PDF-Viewer - z.B. die kostenlose Adobe Digital Editions-App.
Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.
aus dem Bereich