Nicht aus der Schweiz? Besuchen Sie lehmanns.de

Temporal Bone (eBook)

An Imaging Atlas
eBook Download: PDF
2010 | 2010
X, 109 Seiten
Springer Berlin (Verlag)
978-3-642-02210-4 (ISBN)

Lese- und Medienproben

Temporal Bone - John I. Lane, Robert J. Witte
Systemvoraussetzungen
139,09 inkl. MwSt
(CHF 135,85)
Der eBook-Verkauf erfolgt durch die Lehmanns Media GmbH (Berlin) zum Preis in Euro inkl. MwSt.
  • Download sofort lieferbar
  • Zahlungsarten anzeigen

Imaging of the temporal bone has recently been advanced with multidetector CT and high-field MR imaging to the point where radiologists and clinicians must familiarize themselves with anatomy that was previously not resolvable on older generation scanners. Most anatomic reference texts rely on photomicrographs of gross temporal bone dissections and low-power microtomed histological sections to identify clinically relevant anatomy. By contrast, this unique temporal bone atlas uses state of the art imaging technology to display middle and inner ear anatomy in multiplanar two- and three-dimensional formats. In addition to in vivo imaging with standard multidetector CT and 3-T MR, the authors have employed CT and MR microscopy techniques to image temporal bone specimens ex vivo, providing anatomic detail not yet attainable in a clinical imaging practice. Also included is a CD that allows the user to scroll through the CT and MR microscopy datasets in three orthogonal planes of section.

The Temporal Bone 2
Title Page 3
Copyright Page 4
Preface 5
Acknowledgments 7
Contents 9
Chapter 1 11
Imaging Technique 11
Imaging Microscopy 11
CT Microscopy 11
MR Microscopy 11
Clinical Imaging 12
Multidetector CT 12
High Field MR 12
Postprocessing 13
References 15
Chapter 2 16
Anatomy 16
Surface Anatomy 16
Skin Surface 16
Bone Surface 16
Bony External Auditory Canal and Tympanic Membrane 18
Middle Ear Space 18
The Auditory Ossicles 20
The Inner Ear 20
Reference 37
Chapter 3 38
Multiplanar Atlas 38
Temporal Bone Imaging: Historical Perspectives 38
The Axial Plane (in the Plane of the Lateral Semicircular Canal) 39
The Coronal Plane (Perpendicular to the Plane of the Lateral Semicircular Canal) 49
Pöschl Plane (Short Axis Plane of the Temporal Bone) 60
Stenvers Plane (Long Axis Plane of the Temporal Bone) 73
References 83
Chapter 4 85
Advanced Imaging Applications 85
References 106
Chapter 5 107
Imaging Microscopy of the Temporal Bone: An Anatomy Tutorial 107
Introduction 107
Temporal Bone Anatomy Tool 107
Virtual Endoscopy Video Player 107
Glossary 109
Index 116

"1 Imaging Technique (p. 1-2)

Imaging Microscopy

The gold standard for studying temporal bone anatomy has been histological sectioning by microtome following chemical fi xation and deossifi cation of the temporal bone specimen. This process introduces signifi cant artifacts visible even at low power magnifi cation. Although imaging microscopy cannot compete with histology at higher powers of magnifi cation (i.e., the cellular level), resolution at the 20–100 mm level is achievable, allowing study of the temporal bone without the aforementioned artifacts induced by fi xation and sectioning.

CT Microscopy

Computed tomography (CT) microscopy has been primarily used in the imaging of small animals in the research laboratory. There are several obvious advantages to imaging microscopy in the study of the temporal bone compared with standard microtomed histological preparations. MicroCT avoids signifi cant tissue destruction and artifacts introduced during the sectioning process such as fractures, soft tissue tears, fl uid, blood or bone dust in the pneumatized spaces, variable section thickness, and wrinkling, which can occur during the mounting process. Specimen preparation was critical to acquiring the best possible imaging dataset.

Despite a careful technique, we encountered small amounts of fl uid and bone dust in the middle ear space. Air–bone interfaces also caused some minor beam-hardening artifact. The temporal bone specimen used in this atlas was harvested from a male cadaver using the block technique, as described by Gulya [1]. The specimen had to be further reduced in size to a maximal diameter of 2.5 cm and to 4 cm in length in order to fi t properly in the microCT scanner.

The specimen was scanned without decalcifi cation or additional fi xation. The microCT scanning technique used to produce the images in this atlas has been previously described in the literature [2]. MicroCT scanning differs from clinical scanning in that the object is rotated between the tube and camera, which are stationary. The specimen is placed on a rotating stage, which turns 360° about its vertical axis in 0.5° increments. At each angle an X-ray exposure is recorded on the charge-coupled device (CCD) camera.

A single acquisition using a 20-mm slice thickness will cover approximately 2 cm of tissue. Our specimen was scanned in two acquisitions, each taking 8 h at 35 KV and 50 mAs. The two volume acquisitions were then combined using the Analyze 3-D voxel registration program, as described by Hanson et al. and Camp et al. [3, 4]. The fi rst image volume was padded with zerovalued voxels to enlarge the volume enough to contain the entire reassembled volume. The region of overlap between the two acquisitions was used to automatically register the second acquisition to the fi rst. Then, an appropriate “crossover” section was determined, and the whole volume assembled. The entire volume dataset consisted of 20 mm cubic voxels. "

Erscheint lt. Verlag 20.4.2010
Zusatzinfo X, 109 p.
Verlagsort Berlin
Sprache englisch
Themenwelt Medizin / Pharmazie Medizinische Fachgebiete Neurologie
Medizinische Fachgebiete Radiologie / Bildgebende Verfahren Radiologie
Studium 2. Studienabschnitt (Klinik) Anamnese / Körperliche Untersuchung
Schlagworte anatomy • Bone • Computed tomography (CT) • Ear • Imaging Microscopy • MR imaging • Post-processing • Temporal Bone Atlas
ISBN-10 3-642-02210-3 / 3642022103
ISBN-13 978-3-642-02210-4 / 9783642022104
Haben Sie eine Frage zum Produkt?
PDFPDF (Wasserzeichen)
Größe: 14,1 MB

DRM: Digitales Wasserzeichen
Dieses eBook enthält ein digitales Wasser­zeichen und ist damit für Sie persona­lisiert. Bei einer missbräuch­lichen Weiter­gabe des eBooks an Dritte ist eine Rück­ver­folgung an die Quelle möglich.

Dateiformat: PDF (Portable Document Format)
Mit einem festen Seiten­layout eignet sich die PDF besonders für Fach­bücher mit Spalten, Tabellen und Abbild­ungen. Eine PDF kann auf fast allen Geräten ange­zeigt werden, ist aber für kleine Displays (Smart­phone, eReader) nur einge­schränkt geeignet.

Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen dafür einen PDF-Viewer - z.B. den Adobe Reader oder Adobe Digital Editions.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen dafür einen PDF-Viewer - z.B. die kostenlose Adobe Digital Editions-App.

Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.

Mehr entdecken
aus dem Bereich

von Marija Pinto

eBook Download (2023)
Urban & Fischer Verlag - Lehrbücher
CHF 26,35