Fault Location on Power Networks (eBook)
X, 425 Seiten
Springer London (Verlag)
978-1-84882-886-5 (ISBN)
Fault Location on Power Lines enables readers to pinpoint the location of a fault on power lines following a disturbance. The nine chapters are organised according to the design of different locators. The authors do not simply refer the reader to manufacturers' documentation, but instead have compiled detailed information to allow for in-depth comparison.
Fault Location on Power Lines describes basic algorithms used in fault locators, focusing on fault location on overhead transmission lines, but also covering fault location in distribution networks. An application of artificial intelligence in this field is also presented, to help the reader to understand all aspects of fault location on overhead lines, including both the design and application standpoints.
Professional engineers, researchers, and postgraduate and undergraduate students will find Fault Location on Power Lines a valuable resource, which enables them to reproduce complete algorithms of digital fault locators in their basic forms.
Murari Mohan Saha received a B.Sc.E.E. from Bangladesh University of Technology (BUET), Dhaka, in 1968 and completed his M.Sc.E.E. in 1970. From 1969-1971, he was a lecturer at the E.E. department at BUET. In 1972 he completed his M.S.E.E and in 1975 he was awarded his PhD from The Technical University of Warsaw, Poland. He joined ASEA, Sweden, in 1975 as a development engineer and is currently a senior research and development engineer at ABB AB , Västerås, Sweden. His areas of interest are the measurement of transformers; power system analysis and simulation; and digital protective relays.
Jan Izykowski received his MSc, PhD and D.Sc. (habilitation) degrees from the Wroclaw University of Technology (WUT) in 1973, 1976 and 2001, respectively. In 1973 he joined the Institute of Electrical Engineering of the WUT where he is presently an associate professor. Currently he is a director of the Institute of Electric Power Engineering of WUT. He is a senior member of IEEE (USA). His research interests are in power system transients simulation and analysis; power system protection and control; fault location; and transient phenomena of instrument transformers.
Eugeniusz Rosolowski received his MSc degree in Electrical Engineering from the WUT in 1972. From 1974 to 1977, he studied in Kyiv Politechnical Institute (Ukraine) from where he received his PhD in 1978. In 1993 he received his D.Sc. (habilitation) from the WUT, where he is presently a professor. He is a senior member of IEEE (USA). His research interests are in power system analysis; EMTP application; digital protection; and intelligence system application to power system protection.
Fault Location on Power Lines enables readers to pinpoint the location of a fault on power lines following a disturbance. The nine chapters are organised according to the design of different locators. The authors do not simply refer the reader to manufacturers' documentation, but instead have compiled detailed information to allow for in-depth comparison.Fault Location on Power Lines describes basic algorithms used in fault locators, focusing on fault location on overhead transmission lines, but also covering fault location in distribution networks. An application of artificial intelligence in this field is also presented, to help the reader to understand all aspects of fault location on overhead lines, including both the design and application standpoints.Professional engineers, researchers, and postgraduate and undergraduate students will find Fault Location on Power Lines a valuable resource, which enables them to reproduce complete algorithms of digital fault locators in their basic forms.
Murari Mohan Saha received a B.Sc.E.E. from Bangladesh University of Technology (BUET), Dhaka, in 1968 and completed his M.Sc.E.E. in 1970. From 1969-1971, he was a lecturer at the E.E. department at BUET. In 1972 he completed his M.S.E.E and in 1975 he was awarded his PhD from The Technical University of Warsaw, Poland. He joined ASEA, Sweden, in 1975 as a development engineer and is currently a senior research and development engineer at ABB AB , Västerås, Sweden. His areas of interest are the measurement of transformers; power system analysis and simulation; and digital protective relays.Jan Izykowski received his MSc, PhD and D.Sc. (habilitation) degrees from the Wroclaw University of Technology (WUT) in 1973, 1976 and 2001, respectively. In 1973 he joined the Institute of Electrical Engineering of the WUT where he is presently an associate professor. Currently he is a director of the Institute of Electric Power Engineering of WUT. He is a senior member of IEEE (USA). His research interests are in power system transients simulation and analysis; power system protection and control; fault location; and transient phenomena of instrument transformers. Eugeniusz Rosolowski received his MSc degree in Electrical Engineering from the WUT in 1972. From 1974 to 1977, he studied in Kyiv Politechnical Institute (Ukraine) from where he received his PhD in 1978. In 1993 he received his D.Sc. (habilitation) from the WUT, where he is presently a professor. He is a senior member of IEEE (USA). His research interests are in power system analysis; EMTP application; digital protection; and intelligence system application to power system protection.
Fault Location – Basic Concept and Characteristic of Methods.- Network Configurations and Models.- Power-line Faults – Models and Analysis.- Signal Processing for Fault Location.- Measurement Chains of Fault Locators.- One-end Impedance-based Fault-location Algorithms.- Two-end and Multi-end Fault-location Algorithms.- Fault Location in Distribution Networks.- Artificial Intelligence Application.
Erscheint lt. Verlag | 25.11.2009 |
---|---|
Reihe/Serie | Power Systems | Power Systems |
Zusatzinfo | X, 425 p. |
Verlagsort | London |
Sprache | englisch |
Themenwelt | Informatik ► Theorie / Studium ► Künstliche Intelligenz / Robotik |
Informatik ► Weitere Themen ► CAD-Programme | |
Technik ► Elektrotechnik / Energietechnik | |
Technik ► Nachrichtentechnik | |
Wirtschaft ► Betriebswirtschaft / Management | |
Schlagworte | algorithms • Artificial Intelligence • Automation • Complexity • CP4622 • Digital Measurement • fault analysis • Fault Location • Intelligence • Knowledge • Network • Overhead Power Lines • Power Systems • Quality Control, Reliability, Safety and Risk • Reliability • Signal • Transmission |
ISBN-10 | 1-84882-886-1 / 1848828861 |
ISBN-13 | 978-1-84882-886-5 / 9781848828865 |
Haben Sie eine Frage zum Produkt? |
Größe: 5,5 MB
DRM: Digitales Wasserzeichen
Dieses eBook enthält ein digitales Wasserzeichen und ist damit für Sie personalisiert. Bei einer missbräuchlichen Weitergabe des eBooks an Dritte ist eine Rückverfolgung an die Quelle möglich.
Dateiformat: PDF (Portable Document Format)
Mit einem festen Seitenlayout eignet sich die PDF besonders für Fachbücher mit Spalten, Tabellen und Abbildungen. Eine PDF kann auf fast allen Geräten angezeigt werden, ist aber für kleine Displays (Smartphone, eReader) nur eingeschränkt geeignet.
Systemvoraussetzungen:
PC/Mac: Mit einem PC oder Mac können Sie dieses eBook lesen. Sie benötigen dafür einen PDF-Viewer - z.B. den Adobe Reader oder Adobe Digital Editions.
eReader: Dieses eBook kann mit (fast) allen eBook-Readern gelesen werden. Mit dem amazon-Kindle ist es aber nicht kompatibel.
Smartphone/Tablet: Egal ob Apple oder Android, dieses eBook können Sie lesen. Sie benötigen dafür einen PDF-Viewer - z.B. die kostenlose Adobe Digital Editions-App.
Zusätzliches Feature: Online Lesen
Dieses eBook können Sie zusätzlich zum Download auch online im Webbrowser lesen.
Buying eBooks from abroad
For tax law reasons we can sell eBooks just within Germany and Switzerland. Regrettably we cannot fulfill eBook-orders from other countries.
aus dem Bereich